GSS (Gas Sensing Solutions Ltd.) designs and manufactures a range of award winning CO₂ sensors from its base in Scotland, UK. The company makes its own mid-range infrared LEDs, which are used as the core technology platform to enable fastest response times, lowest power consumption and longest product lifetime.
GSS sensors are used in diverse markets, including healthcare, industrial safety, food packaging, air quality and transportation. From typical everyday applications, to the most niche and unusual – GSS sensors have just about done it all, so the possibilities are endless.
Download:
Low Power
Serie | CozIR®-A | CozIR®-Blink | CozIR®-LP | CozIR®-LP2 | CozIR®-LP3 |
Measurement Range | 0-2000ppm 0-5000ppm 0-10000ppm (0-1%) |
0-2000ppm 0-5000ppm 0-10000ppm (0-1%) |
0-2000ppm 0-5000ppm 0-10000ppm (0-1%) |
0-2000ppm 0-5000ppm 0-10000ppm (0-1%) |
0-2000ppm 0-5000ppm 0-10000ppm (0-1%) |
Measurement Rate (Hz) | 2Hz | 2Hz | 2Hz | 2Hz | 2Hz |
Digital Interface Type | UART | UART or I²C | UART | UART or I²C | UART or I²C |
Analogue Output | Yes / Option | No | No | No | No |
Temp & RH Sensor | Option | No | No | No | No |
Operating Temp Range | 0°C bis 50°C oder -25°C bis 55°C | 0°C bis 50°C | 0°C bis 50°C | 0°C bis 50°C | 0°C bis 50°C |
Sampling Method | Diffusion | Diffusion | Diffusion | Diffusion | Diffusion |
Features | Protective Casing | 26µW per reading | Digital Alarm |
High Speed
Serie | SprintIR®-6S | SprintIR®-R | SprintIR®-W |
Measurement Rate (Hz) | 0-5% 0-20% 0-60% 0-100% |
0-5% 0-20% 0-60% 0-100% |
0-5% 0-20% 0-60% 0-100% |
Measurement Rate (Hz) | 20Hz | 20Hz | 20Hz |
Digital Interface Type | UART | UART | UART |
Analogue Output | No | No | Yes / Option |
Temp & RH Sensor | No | No | Option |
Operating Temp Range | 0°C to 50°C | 0°C to 50°C | 0°C to 50°C or -25°C to 55°C |
Sampling Method | Flow Through | Flow Through | Diffusion or Flow Through |
Features | 20ms response time | 20ms response time |
Wide Range
Serie | ExplorIR®-M | ExplorIR®-W |
Measurement Range | 0-5% 0-20% 0-60% 0-100% |
0-5% 0-20% 0-60% 0-100% |
Measurement Rate (Hz) | 2Hz | 2Hz |
Digital Interface Type | UART | UART |
Analogue Output | No | Yes / Option |
Temp & RH Sensor | No | Option |
Operating Temp Range | 0°C to 50°C | 0°C to 50°C or -25°C to 55°C |
Sampling Method | Diffusion | Diffusion or Flow Through |
Features | ultra compact |
We are looking forward to a good cooperation with you!
→ go back to product overview